From the wide range of rubber products available, we offer the cables with following
varieties of Rubber insulation & sheaths. |
- V.I.R. – Vulcanised Indian Rubber
- H.O.F.R. - Heat, Oil & Fire Resistant.
- E.P.R. - Ethylene Propylene Rubbers.
- P.C.P. - Poly Chlore Prene
- C.S.P. - Chloro Sulphynated Polythene
- SILICON
|
Depending on various applications, different composition of rubbers are used. The technical parameters and maintained to provide long term service life. Here below is given the range of products supplied by us. |
WELDING CABLE - COPPER CONDUCTOR
GENERAL PURPOSE / HOFR RUBBER COMPOUND COVERED. |
| |
| Nominal Cross Sectional area of Conductor |
Number/ Nom. Dia of Wires |
Thickness of Insulation
(Nom) |
General Purpose
Compund |
HOFR
Compund |
|
| |
|
Current Rating at max. duty cycle |
| Amps. |
|
Amps |
| mm2 |
mm |
mm |
100%
|
60%
|
30%
|
100%
|
60%
|
30% |
| 25 |
355/0.3 |
2.0 |
100 |
129 |
183 |
144 |
186 |
263 |
| 35 |
495/0.3 |
2.0 |
123 |
159 |
225 |
176 |
227 |
321 |
| 50 |
707/0.3 |
2.2 |
155 |
200 |
283 |
222 |
287 |
405 |
| 70 |
990/0.3 |
2.4 |
196 |
253 |
385 |
280 |
361 |
511 |
| 95 |
1344/0.3 |
2.6 |
237 |
306 |
433 |
339 |
438 |
619 |
| 120 |
1697/0.3 |
2.8 |
283 |
365 |
517 |
404 |
522 |
738 |
|
|
|
| |
| Note : |
Supplied in 100 mtrs. Length in coil packing.
*The number & diameter of conductor strands are for reference only. |
| |
|
| CONSTRUCTION : |
| Conductor: |
|
Aluminium conductor multistrand flexible. |
| Separator: |
|
Polyester Tape / Melinex Tape. |
| Covering: |
|
General purpose compound.
1. SE1 type or SE3
2. Colour : Black/Orange |
|
| |
| MULTI CORE FLEXIBLE - COPPER CONDUCTOR |
| GENERAL PURPOSE / HOFR / EPR / CSP / SILICON INSULATED & SHEATH COMPOUND |
| |
Nominal Cross Sectional area of Conductor |
Nominal Thickness of Insulation (per core) |
NOMINAL SHEATH THICKNESS |
| Single Core |
Two Core
|
Three Core
|
Four Core |
|
mm2 |
mm |
mm |
mm |
mm |
mm |
| 0.50 |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
| 0.75 |
1.00 |
11.00 |
1.00 |
1.00 |
1.10 |
| 1.00 |
1.00 |
1.00 |
1.00 |
1.10 |
1.10 |
| 1.50 |
1.00 |
1.00 |
1.10 |
1.10 |
1.10 |
| 2.50 |
1.00 |
1.00 |
1.10 |
1.10 |
1.10 |
| 4.00 |
1.00 |
1.00 |
1.20 |
1.20 |
1.20 |
| 6.00 |
1.00 |
1.60 |
2.00 |
2.10 |
2.50 |
| 10.00 |
1.20 |
1.80 |
2.40 |
2.50 |
2.70 |
| 16.00 |
1.20 |
1.90 |
2.50 |
2.70 |
2.90 |
| 25.00 |
1.40 |
2.00 |
3.20 |
3.30 |
3.40 |
| 35.00 |
1.40 |
2.20 |
3.30 |
3.40 |
3.50 |
| 50.00 |
1.60 |
2.40 |
3.50 |
3.60 |
3.70 |
| 70.00 |
1.60 |
2.60 |
3.60 |
3.70 |
3.90 |
| 95.00 |
1.80 |
2.80 |
3.80 |
4.00 |
4.10 |
| 120.00 |
1.80 |
3.00 |
4.00 |
4.10 |
4.30 |
| 150.00 |
2.00 |
3.20 |
4.20 |
4.30 |
4.50 |
| 185.00 |
2.20 |
3.40 |
4.30 |
4.50 |
4.80 |
| 240.00 |
2.40 |
3.50 |
4.60 |
4.80 |
5.10 |
| 300.00 |
2.60 |
3.50 |
4.90 |
5.10 |
5.40 |
|
| |
| Note : |
Supplied in 100 mtrs. Length in coil packing.
*The number & diameter of conductor strands are for reference only. |
| |
|
| CONSTRUCTION : |
| Conductor: |
|
(a) Anealed Tinned/Bare Copper Conductor as per IS:8130 |
| Insulation: |
|
(i) General Service Elastomeric – IE1Type
(ii) Heat Resisting Elastomeric – IE2 Type
(iii) Tape optional |
| Filler: |
|
2-3 and 4 core laid up |
| Sheath: |
|
General Service Insulation and Heat Resistant Sheath. |
|
| |
| FAN FLEXIBLE WIRES |
| ELASTOMER INSULATED AND OVERALL COTTON/SILK BRAIDED |
| |
Nominal Cross Sectional area of Conductor |
Number/ Nom. Dia
of Wires* |
Thickness of
Insulation (Nom) |
MAX OVER ALL DIAMETER |
| Two Core |
Three Core |
|
|
| mm2 |
mm |
mm |
mm |
mm |
| 0.5 |
16/0.2
|
1.0 |
8.3 |
9.0 |
| 0.75 |
24/0.2
|
1.0 |
8.7 |
9.5 |
| 1.0 |
32/0.2 |
1.0 |
9.1 |
9.9 |
| 1.5 |
48/0.2
|
1.0 |
9.7 |
10.5 |
| 2.5 |
80/0.2
|
1.0 |
10.5 |
11.3 |
| 4.0 |
128/0.2
|
1.0 |
11.7 |
12.6 |
|
| |
| Note : |
Supplied in 100 Mtrs. Length in coil packing.
*The |
| |
|
| |
| |
|
|
|
|